Factory Supply Sx460 Avr Generator Automatic Voltage Regulator
SKU #7032060379172
Rodzaj: Generators
Dostępność: W magazynie
Ceny od: $ 38.39
BEZPŁATNA ŚLEDZONA WYSYŁKA NA CAŁYM ŚWIECIE
Specifications:
Model Number: sx460 avr
Voltage:95~132VACor190~264VAC1 phase, jumper selectable
Frequency?50160 Hz, selectable
Voltage?Max. 90 VDC @ 207 VAC
Current?Continuous 4A ?Intermittent 10A for 10 sec.
Resistance?Min.15 ohm
<+ 1.5% ( with 4% engine governing )
Voltage Build-up?Residual voltage at AVR terminal> 5 VAC
Thermal Drift?0.05% per C change in AVR ambient
External Volts Adjustment?7% with 1K ohm 1 watt trimmer
Unit Power Dissipationt?Max.10 watt
Under Frequency Protection?Set point ?95% Hz
( UFRO )? Slope 170% down to 30 Hz
Soft Start Ramp Time?2 sec.
Dimensions?135mmL*100mmW*49mmH
Weight?243g t 2%
ConnectF1, F2 to DC output port.
Connect the sensing port at 7, 8 (the factory setupis 220V, if 110V is required, please join 3, 4)
External voltage regulator is as Figure 4.
Connect a jumper from COM to the 50Hz terminal for 50Hz operation.
Note :
please install 5A 250V fuse at power input portas Figure 4
Produkt nie pasuje do opisu? Skontaktuj się z nami w ciągu 30 dni od jego otrzymania!
W przypadku rezygnacji pieniądze zostaną zwrócone na Twoje konto w ciągu 3 dni.
Model Number: sx460 avr
Voltage:95~132VACor190~264VAC1 phase, jumper selectable
Frequency?50160 Hz, selectable
Voltage?Max. 90 VDC @ 207 VAC
Current?Continuous 4A ?Intermittent 10A for 10 sec.
Resistance?Min.15 ohm
<+ 1.5% ( with 4% engine governing )
Voltage Build-up?Residual voltage at AVR terminal> 5 VAC
Thermal Drift?0.05% per C change in AVR ambient
External Volts Adjustment?7% with 1K ohm 1 watt trimmer
Unit Power Dissipationt?Max.10 watt
Under Frequency Protection?Set point ?95% Hz
( UFRO )? Slope 170% down to 30 Hz
Soft Start Ramp Time?2 sec.
Dimensions?135mmL*100mmW*49mmH
Weight?243g t 2%
ConnectF1, F2 to DC output port.
Connect the sensing port at 7, 8 (the factory setupis 220V, if 110V is required, please join 3, 4)
External voltage regulator is as Figure 4.
Connect a jumper from COM to the 50Hz terminal for 50Hz operation.
Note :
please install 5A 250V fuse at power input portas Figure 4